Household is decorated in, RF connector ore electric circuitry to dark apply construction wiring method. Dark apply wiring is nice, but is not easy to repair, being less intelligent remained statistically significant hidden danger, etc. Pay particular attention to the following points in the construction. 
(1) before the construction, we must give full consideration to various functional areas needed for the electrical and lighting equipment, and based on each wire roughly corresponding matching wire cross-sectional area. Under the condition of the economic conditions permit, we should try to RF Cable Assembly
 dopt high quality copper sheathed wire junction box and dark. 
(2) drawing room wiring circuit distribution in each layer, and all sorts of lamps and lanterns, switch, socket and switch board set coordinate and height, to determine the line and the direction of the branch. Cabling general from beginning to end all the way at the end of the line terminal block direction construction. Wire had better choose the different color to identify the different circuits. 
(3) it is best to wear outside power supply fire retardant laying pipes. In combustible construction smallpox barn, be sure to add wear fire retardant pipes, and cannot be installed capacitor, inflammable and explosive electric switch electric appliances, at the same time the bird should be set the power switch, when it is necessary for cut off power supply. So the wire connection should be carried out within the terminal block. 
(4) indoor each branch circuit the total capacity should not be more than 3000 w, every single phase circuit of the load current is generally not more than 15 a. Domestic power users shall set up special line, such as air conditioning. Bathroom shower equipment to maintain a certain distance, such as the power switch and moisture-proof measures. Each appropriate USES single-phase circuit automatic air switch control and protection, switchboard shall be equipped with the leakage protector. 
(5) switch installation height 1200 ~ 1350 mm from the ground commonly, socket height is generally 200 ~ 300 mm, height of panel with 1800 ~ 2000 mm advisable. 
(6) wiring has been completed, should according to the design requirements for inspection, testing, inspection and correct rear can construction for other process. At the same time, construction personnel to account to the other processes of construction personnel, in case damage when drilling, hole, screw nails has good line construction. 